Norsound NOR200 Finger Protection Single Set – 1950mm
Norsound NOR200 Finger Protection Single Set – 1950mm is a surface-mounted safety device designed to help prevent fingers from entering the hazardous gap created between a timber door leaf and frame as the door opens.
The flexible PVC protector bridges the changing hinge-side gap throughout normal door operation. When correctly selected, fitted and maintained, it helps reduce the risk of fingers becoming trapped or crushed as the door closes.
The Single Set is supplied in a fixed 1950mm length with a choice of Silver Grey or White.
Single-Side Hinge-Gap Protection
The NOR200 Single Set protects the main hinge-gap side of a door.
It is suitable where:
- The opening-side hinge gap is the identified trapping hazard
- Only one side of the door is accessible
- The opposite knuckle side is protected separately
- A replacement single-side protector is required
The product does not include the separate knuckle-side protector used on the opposite face of the hinged edge.
Where both sides are accessible, use the appropriate additional knuckle protector or the NOR200 Full Set.
Flexible PVC Construction
NOR200 is manufactured from flexible PVC. The material is designed to extend and fold as the door moves while maintaining a protective barrier across the hinge gap.
The flexible construction allows it to accommodate suitable timber doorsets with different hinge and frame arrangements, subject to the product’s fitting requirements.
The protector must remain free to move without:
- Becoming excessively stretched
- Twisting or buckling
- Pulling away from its fixing surfaces
- Contacting the hinges
- Preventing the door from opening or closing correctly
Surface-Mounted Installation
NOR200 is fitted to the surface of the door and frame rather than being recessed into a routed channel.
This makes it suitable for installation on compatible existing timber doorsets where the available surfaces and door geometry allow the protector to be mounted correctly.
The manufacturer identifies two fixing methods:
- Self-adhesive fixing
- Pinned fixing
The exact fixing arrangement should follow the current fitting instructions supplied with the product.
Suitable for Wide Door-Opening Angles
The NOR200 is designed for suitable doors opening up to 180 degrees.
Actual compatibility depends on:
- The hinge type and projection
- The door-leaf thickness
- The frame and door-stop profile
- The available fixing surfaces
- The position of adjacent ironmongery
- The door’s normal opening angle
Check the door through its complete operating range before completing the installation.
Tested for Repeated Operation
The NOR200 has been tested through 250,000 operating cycles.
It is also listed as SKG certified to EN 16654 and NEN 8654.
Cycle testing demonstrates durability under the applicable test conditions, but the protector must still be inspected regularly. Frequently operated doors may require more frequent checks of the flexible PVC and fixing points.
Typical Applications
NOR200 may be used on suitable internal timber doors where a hinge-side finger-trapping risk has been identified.
Typical locations can include:
- Schools and nurseries
- Healthcare environments
- Care facilities
- Libraries and community buildings
- Hospitality and public buildings
- Other areas used by children or vulnerable occupants
Final selection should form part of the site’s door-safety risk assessment.
Available Colours
The stocked colour options are:
- Silver Grey — identified as Grey in the manufacturer’s technical data
- White
Select the finish that best coordinates with the door leaf, frame and surrounding ironmongery.
Fixed 1950mm Length
Both variations are supplied in a fixed 1950mm length.
Before ordering, confirm that the protector will fit the intended door while remaining clear of:
- The floor or threshold
- The frame head
- Hinges and hinge covers
- Door closers
- Intumescent and smoke seals
- Other adjacent ironmongery
Only trim the product where permitted by the current fitting instructions.
Use on Fire-Resisting Doors
NOR200 is a finger-protection accessory rather than an intumescent or smoke seal.
Before installing it on a fire-resisting door, confirm that:
- The doorset manufacturer or supporting evidence permits the accessory
- The proposed fixing method will not damage critical doorset components
- The protector will not obstruct hinges, smoke seals or intumescent seals
- The door can continue to close fully
- The latch and self-closing device remain effective
NOR200 does not independently provide a fire-resistance or smoke-control classification.
Key Benefits
- Helps protect the main hinge-side trapping gap
- Surface-mounted installation
- Suitable for compatible timber doorsets
- Self-adhesive or pinned fixing
- Flexible PVC construction
- Suitable for door openings up to 180 degrees
- Tested through 250,000 operating cycles
- SKG certified to EN 16654 and NEN 8654
- Available in Silver Grey and White
Important Selection Advice
Before ordering, confirm:
- That single-side protection is suitable
- Whether the opposite knuckle side also requires protection
- That the 1950mm length suits the door
- That the door and frame provide suitable fixing surfaces
- That the normal opening angle is compatible
- That the protector will remain clear of hinges and seals
- That installation is permitted on any fire-resisting doorset
Norsound NOR200 Finger Protection Single Set – 1950mm Technical Specifications
| Product Name |
Norsound NOR200 Finger Protection Single Set – 1950mm |
| Product Reference |
NOR200/SS |
| Product Type |
Surface-mounted single-side door finger protector |
| Protected Area |
Main hinge gap between a timber door leaf and frame |
| Opposite Knuckle Protector Included? |
No |
| Application |
Hinge-gap side of suitable timber doorsets |
| Material |
Flexible PVC |
| Length |
1950mm |
| Installation Type |
Surface mounted |
| Fixing |
Self-adhesive or pinned |
| Maximum Published Door Opening |
Up to 180 degrees, subject to the actual door and hinge geometry |
| Cycle Testing |
250,000 operating cycles |
| Certification |
SKG certified to EN 16654 and NEN 8654 |
| Stocked Colours |
Silver Grey and White |
| Manufacturer Colour Descriptions |
Grey and White |
| Unit of Sale |
One single-side protector |
| Fire Seal? |
No |
| Standalone Fire Rating? |
No — installation on a fire-resisting door must be permitted by the complete doorset evidence |
Available Variations and Product Codes
| Colour |
Length |
Set Type |
Product Code |
| Silver Grey |
1950mm |
Single set |
NOR200/SS/GRY |
| White |
1950mm |
Single set |
NOR200/SS/WHT |
Variation Summary
| Colour Options |
Length Options |
Set Options |
Total Variations |
| Silver Grey and White |
1950mm |
Single set |
2 |
Product-Code Structure
The stocked Product Codes use the following format:
NOR200 / SS / Colour
- NOR200: product range
- SS: single set
- GRY: Silver Grey
- WHT: White
Use on Pivoted and Double-Swing Doors
The manufacturer states that one NOR200 should be installed on either side of the door where protection is required for pivoted or double-swing applications.
Confirm the complete door geometry and fitting arrangement before specifying multiple single sets.
Not Included
- Separate knuckle-side protector
- Door hinges or pivots
- Door closer
- Intumescent or smoke seals
- Any standalone fire-resistance classification
Inspection Requirements
Inspect the protector regularly for:
- Loose adhesive edges
- Loose or missing pins where used
- Tears, splits or punctures
- Permanent stretching or deformation
- Excessive tension at the full opening angle
- Interference with the hinges or door seals
- Obstruction of the door-closing action
Replace damaged material rather than relying on temporary repairs.
How to Install the Norsound NOR200 Finger Protection Single Set – 1950mm
The NOR200 Single Set is surface mounted across the main hinge gap between the timber door leaf and frame.
The precise orientation, fixing positions and any permitted trimming must follow the fitting instructions supplied with the current product.
1. Inspect the Door
Before installation, confirm that:
- The door leaf and frame are secure.
- The hinges or pivots are correctly fixed and adjusted.
- The door opens and closes smoothly.
- The main hinge gap is the area requiring protection.
- The normal door opening is within the supported range.
- Suitable fixing surfaces are available.
- Installation is permitted where the door is fire resisting.
Correct any hinge, alignment, latching or closing fault before fitting the protector.
2. Check the Length and Clearances
Offer the 1950mm protector to the door and frame before removing any adhesive release liner.
Confirm that it:
- Fits beneath the frame head
- Remains clear of the floor or threshold
- Does not obstruct hinges or pivots
- Remains clear of door seals
- Does not interfere with adjacent ironmongery
Only trim the protector where this is expressly permitted by the current fitting guide.
3. Prepare the Mounting Surfaces
Clean the areas of the door and frame that will receive the fixing edges.
The surfaces must be:
- Clean and dry
- Free from dust and loose material
- Free from grease, polish and silicone
- Free from peeling paint or unstable finishes
- Suitable for self-adhesive or pinned fixing
Allow the surfaces to dry completely before fitting the protector.
4. Dry-Position the Protector
Position NOR200 across the hinge gap without removing the backing liner.
Move the door slowly through its normal opening range and check that:
- The protector bridges the gap correctly.
- The fixing edges sit flat against the door and frame.
- The flexible section does not twist.
- The protector remains clear of the hinges.
- It does not become excessively stretched at full opening.
5. Apply the First Fixing Edge
Remove a short section of the adhesive release liner from the first fixing edge.
Align the protector carefully and press the fixing edge firmly onto the prepared surface.
Continue removing the liner progressively while maintaining a straight vertical alignment.
Do not stretch the flexible PVC during installation.
6. Apply the Opposing Fixing Edge
Align the second fixing edge with the corresponding surface on the door or frame.
Remove the release liner progressively and press the edge firmly into position.
Check that the flexible centre remains correctly aligned across the hinge gap.
7. Add Pinned Fixing Where Required
Where the specified installation uses pins, fit them only in the positions identified by the current fitting instructions.
Ensure that the fixings:
- Enter suitable substrate
- Remain secure without sharp projections
- Do not damage hinges, seals or concealed components
- Do not puncture or distort the flexible centre
- Do not interfere with door operation
8. Test the Door
Open and close the door slowly through its complete normal operating range.
Confirm that:
- The protector extends and folds smoothly.
- It does not become excessively tight.
- The fixing edges remain secure.
- The door reaches its intended opening position.
- The door closes fully into the frame.
- The latch engages correctly.
- The self-closing device remains effective.
Stop and correct the installation if the protector interferes with the door or begins to detach.
9. Complete the Final Inspection
Check that:
- The complete intended hinge gap is covered.
- The fixing edges are firmly secured.
- All required pins are secure where used.
- No sharp fixing points remain exposed.
- The flexible PVC is not twisted or damaged.
- The protector remains clear of hinges and door seals.
- The door opens, closes and latches correctly.
Maintenance
Inspect the NOR200 regularly, particularly on frequently operated doors.
Replace the protector where it becomes:
- Loose or detached
- Torn, split or punctured
- Permanently stretched or distorted
- Excessively tight during door operation
- Likely to obstruct safe closing
Important Safety Note
The NOR200 Single Set protects one hinge-gap side only.
Where the opposite knuckle side is also accessible, install the appropriate additional protector or use a full-set arrangement.