SKU: N/A

Lorient LAS7001 SI Perimeter Seal

(0 Review)
£0.00
Show VAT
1
Earliest delivery: Calculating... Checking dispatch time...
  • Standard (tracked 48)
    £7.95 for 2-3 working days
  • Next Day (tracked 24)
    £9.95 for Next working day aim
  • Signed Delivery (signed for 24)
    £11.95 for Next working day aim
  • Guaranteed
    £16.95 for 2-3 working days
  • Local Pickup
    FREE - Collection from our Bristol warehouse

Lorient LAS7001 si Perimeter Seal

Lorient LAS7001 si Perimeter Seal is a slimline, face-fixed door seal designed to improve acoustic and smoke containment around the head and jambs of single swing doors.

The seal combines an aluminium carrier with a flexible silicone rubber gasket. It is fixed directly onto the existing door stops, allowing the gasket to compress against the face of the closed door and reduce open gaps around the frame.

A decorative PVC cover strip conceals the fixing screws after installation, creating a neat and unobtrusive finish. The LAS7001 si can normally be installed without removing the door from its hinges, making it suitable for both new installations and upgrades to existing doors.

What is the LAS7001 si used for?

The LAS7001 si is used to seal the gaps around the top and sides of a single swing door.

Gaps between the door leaf and frame can allow sound, smoke, draughts, weather and light to pass between adjoining spaces. Installing a correctly adjusted perimeter seal helps create more consistent contact around the closed door.

It is commonly used for:

  • Reducing sound leakage around door edges
  • Improving acoustic containment between rooms
  • Supporting smoke containment around door assemblies
  • Reducing draughts through perimeter gaps
  • Limiting visible light around a closed door
  • Upgrading existing doors with a face-fixed sealing system
  • Creating a continuous seal around the head and jambs

How does the LAS7001 si work?

The LAS7001 si contains a flexible silicone rubber gasket held within a slim aluminium carrier.

When the door closes, the silicone gasket compresses against the face of the door. This helps close the gap between the door and its stops, reducing the open pathways through which sound, smoke, air and light can travel.

The fixing holes in the aluminium carrier are pre-drilled and slotted. This allows the position of the seal to be adjusted during installation so that the gasket makes firm and consistent contact without preventing the door from closing or latching correctly.

Acoustic performance

The LAS7001 si has been acoustically tested to BS EN ISO 10140-2:2010, with Lorient stating performance of up to Rw 33dB.

The quoted performance applies to the relevant tested door assembly and sealing arrangement. It should not be treated as a standalone 33dB rating for the perimeter seal itself.

Final acoustic performance will depend on:

  • The construction and mass of the door leaf
  • The condition and alignment of the frame
  • The adjustment of the LAS7001 si gasket
  • The threshold or automatic drop seal
  • Glazing and door hardware
  • The frame-to-wall junction
  • The quality of installation

The gap beneath the door must also be treated with a suitable threshold or drop seal to create an effective acoustic sealing system.

Smoke containment

The LAS7001 si has been tested to BS EN 1634-3:2004 at ambient and medium temperatures.

Lorient states that the product provides an effective smoke seal up to 200°C and meets the smoke requirements referenced in BS 9999:2017.

Smoke performance depends on the complete door assembly, including the perimeter seals, threshold treatment, door construction and installation quality.

The LAS7001 si is not an intumescent fire seal and should not be treated as a replacement for any required intumescent strips or other fire-door components.

Where is the LAS7001 si installed?

The LAS7001 si is designed for face-fixed installation onto the existing stops at the:

  • Head of the door frame
  • Hinge-side jamb
  • Closing-side jamb

It is intended for single swing doors. The head and jamb lengths are cut and mitred at the upper corners to create a continuous and neat perimeter arrangement.

Suitable applications

The LAS7001 si can be used in a wide range of residential, commercial and public buildings, including:

  • Offices and meeting rooms
  • Schools and education buildings
  • Hotels and hospitality premises
  • Healthcare environments
  • Apartment and residential developments
  • Recording and media rooms
  • Plant rooms and service areas
  • Commercial fit-outs
  • Public buildings
  • Doors requiring an acoustic or smoke-control upgrade

Why choose a face-fixed perimeter seal?

A face-fixed seal can be installed directly onto the existing door stops without machining a groove into the door leaf or frame.

This makes the LAS7001 si particularly useful for retrofit projects where improved sealing is required with relatively little disruption.

The door does not normally need to be removed from its hinges during installation.

LAS7001 si and LAS7003 si — what is the difference?

Both products are face-fixed Lorient perimeter seals, but they use different gasket profiles.

The LAS7001 si uses a rounded silicone compression gasket and is designed primarily for acoustic and smoke containment around correctly aligned single swing doors.

The LAS7003 si uses a larger flexible compression profile designed to accommodate greater variation in the distance between the door face and the stop. It can therefore be useful where a door is slightly warped, unevenly hung or has inconsistent perimeter gaps.

The correct product should be selected according to the door condition, gap arrangement and required tested performance.

Key benefits

  • Improves acoustic containment — helps reduce sound leakage around the top and sides of a door.
  • Tested up to Rw 33dB — acoustic test evidence is available for relevant complete door assemblies.
  • Smoke-tested performance — tested to BS EN 1634-3:2004 at ambient and medium temperatures.
  • Effective smoke sealing up to 200°C — according to Lorient’s current technical data.
  • Flexible silicone gasket — compresses against the closed door face.
  • Face-fixed installation — fitted directly onto existing door stops.
  • No door removal normally required — suitable for straightforward retrofit installation.
  • Adjustable positioning — slotted fixing holes allow accurate gasket adjustment.
  • Concealed fixings — supplied PVC cover strip hides the fixing screws.
  • Durability tested — tested to 100,000 operating cycles.
  • Multiple containment functions — protects against sound, smoke, weather, draught and light.
  • Suitable for timber and metal construction — appropriate fixing screws can be selected for each substrate.
  • Certifire certification — listed under certification reference CF5179.

Which door-bottom seal should be used?

The LAS7001 si seals the head and jambs of the door only. The gap beneath the door must be treated separately.

Lorient recommends combining the LAS7001 si with either:

  • Lorient LAS8001 si Drop Seal
  • Lorient LAS8004 Drop Seal

Lorient also states that the LAS7001 si can be used with practically any suitable threshold seal.

The correct door-bottom product will depend on the door material, available clearance, floor finish and required acoustic, smoke or weather performance.

Helpful advice before buying

Measure the height and width of the door stops before ordering.

Standard individual lengths are available in 1m and 2.1m sizes. A standard single doorset pack contains:

  • 1 x 1m length for the door head
  • 2 x 2.1m lengths for the jambs

The seal should make firm and consistent contact with the closed door without creating excessive closing resistance or preventing the latch from engaging.

For acoustic applications, inspect the complete door assembly. Sound may also pass through:

  • The gap beneath the door
  • A lightweight or hollow door leaf
  • Glazing
  • Keyholes and lock openings
  • Letter plates
  • Ventilation grilles
  • Poorly sealed frame-to-wall junctions

Lorient LAS7001 si Perimeter Seal Technical Specifications

Lorient LAS7001 si is a medium-duty, face-fixed aluminium perimeter seal with a flexible silicone rubber gasket. It is installed onto the existing head and jamb stops of single swing doors.

Product Specification

Product Name Lorient LAS7001 si Perimeter Seal
Manufacturer Lorient
Product Reference LAS7001 si
Product Type Face-fixed compression perimeter seal
Duty Classification Medium duty
Application Sealing the head and jambs of single swing doors
Installation Position Face-fixed to the existing door stops
Approximate Profile Width 27mm
Approximate Profile Depth 6mm
Carrier Material Aluminium
Seal Material Flexible silicone rubber
Cover Strip PVC decorative cover strip supplied to conceal the fixing screws
Operating Method The silicone gasket compresses against the door face when the door closes
Standard Lengths 1m and 2.1m
Single Doorset Pack 1 x 1m head length and 2 x 2.1m jamb lengths
Special Lengths Other lengths may be available to special order
Standard Finish Silver anodised aluminium with grey cover strip and grey silicone rubber gasket
Bronze Finish Bronze anodised aluminium with black cover strip and black silicone rubber gasket
Other Finishes Powder-coated carrier finishes may be available subject to minimum order quantities, non-standard charges and additional lead times
Fixings for Timber Self-tapping wood screws supplied
Fixings for Metal Self-drilling and self-tapping screws available on request
Fixing Holes Pre-drilled and slotted to allow accurate positioning and adjustment
Acoustic Test Standard BS EN ISO 10140-2:2010
Acoustic Test Evidence Up to Rw 33dB within the relevant tested door assembly
Smoke Test Standard BS EN 1634-3:2004 at ambient and medium temperatures
Maximum Stated Smoke-Sealing Temperature Effective smoke seal up to 200°C
BS 9999 Requirement Lorient states that the seal meets the smoke requirement referenced in BS 9999:2017
Durability Tested to 100,000 operating cycles
Containment Characteristics Protects against sound, smoke, weather, draught and light as part of a suitable door assembly
Threshold Compatibility Can be used with practically any suitable threshold seal
Recommended Door-Bottom Seals Lorient LAS8001 si or LAS8004 drop seal
Certifire Certification CF5179
Fire Seal? No — this is an acoustic and smoke perimeter seal and does not replace any required intumescent fire seal

Available Length Options

Option Contents Typical Use
LAS7001 si 1m One 1m perimeter-seal length Door heads, smaller openings, repairs and custom installations
LAS7001 si 2.1m One 2.1m perimeter-seal length Standard-height door jambs and custom perimeter arrangements
Single Doorset Pack 1 x 1m length and 2 x 2.1m lengths One standard single swing door head and two jambs

Finish Options

Finish Carrier Cover Strip Silicone Gasket
Silver Silver anodised aluminium Grey Grey
Bronze Bronze anodised aluminium Black Black
Special Finish Powder-coated aluminium subject to availability Confirm when ordering Confirm when ordering

Suitable Door Types

The LAS7001 si is designed for the head and jambs of single swing doors.

Suitable applications may include:

  • Timber single swing doors
  • Metal single swing doors with suitable fixings
  • Existing doors requiring a retrofit perimeter seal
  • Acoustic door assemblies
  • Smoke-control door applications
  • Internal commercial doors
  • Suitable external doors
  • Public-building and residential doors

Acoustic Performance Note

Lorient states acoustic test evidence of up to Rw 33dB in accordance with BS EN ISO 10140-2:2010.

This performance applies to the complete tested door assembly and should not be interpreted as a standalone rating for the LAS7001 si.

Installing the perimeter seal onto an existing door does not automatically give that door an Rw 33dB rating.

Final performance will depend on:

  • The door-leaf construction and mass
  • The door-frame construction
  • The size and consistency of the perimeter gaps
  • The position and compression of the gasket
  • The threshold or drop-seal arrangement
  • Glazing and ironmongery
  • The frame-to-wall junction
  • Installation workmanship

Smoke Performance Note

The LAS7001 si has been tested to BS EN 1634-3:2004 at ambient and medium temperatures.

Lorient states that the product provides effective smoke sealing up to 200°C and meets the smoke requirement referenced in BS 9999:2017.

The final smoke performance depends on the complete door assembly and specified component arrangement.

The LAS7001 si should not be treated as a replacement for:

  • Required intumescent fire seals
  • A suitable threshold or drop seal
  • Certified smoke-sealing ironmongery details
  • Correct frame and door construction

Threshold Compatibility

The LAS7001 si treats the head and jambs of the door only.

Lorient recommends using it with the LAS8001 si or LAS8004 drop seal, although it can be used with practically any suitable threshold seal.

Where a specific tested acoustic or smoke performance is required, use the component arrangement covered by the relevant test evidence or doorset certification.

Handling and Storage

Store the LAS7001 si:

  • Flat and fully supported
  • In a clean and dry location
  • Away from moisture and site contamination
  • Protected from bending and impact damage
  • With the aluminium, gasket and cover strip protected from scratching

Keep the decorative cover strips with their corresponding carrier lengths and avoid twisting or crushing the silicone gasket before installation.

How to Install the Lorient LAS7001 si Perimeter Seal

Lorient LAS7001 si Perimeter Seal is face-fixed onto the existing stops at the head and jambs of a single swing door.

The head and jamb lengths should be cut with mitred upper corner joints. The pre-slotted fixing holes allow the position of the seal to be adjusted until firm and consistent gasket contact is achieved.

The door does not normally need to be removed from its hinges.

Always check the current Lorient fitting guide and the requirements of the complete doorset before beginning installation.

What You’ll Need

  • LAS7001 si perimeter-seal lengths or single doorset pack
  • Supplied fixing screws
  • Tape measure
  • Pencil or suitable marker
  • Power saw or hand saw suitable for aluminium
  • Mitre box or suitable cutting guide
  • Sharp knife
  • Power drill or hand drill
  • Suitable drill bit for pilot holes
  • Screwdriver
  • Sheet of paper for checking gasket compression
  • Eye protection
  • Suitable gloves

Before You Start

Inspect the door and frame before installing the perimeter seal.

Check that:

  • The door opens, closes and latches correctly
  • The hinges and frame are secure
  • The door stops are stable and suitable for fixing
  • The surfaces are clean and free from loose material
  • The seal will not obstruct locks, hinges or other ironmongery
  • The correct lengths and finish have been supplied
  • A suitable threshold or drop seal has been selected
  • The installation is compatible with any doorset certification

Correct serious door-alignment, hinge or hardware problems before fitting the seal.

The LAS7001 si can be adjusted to achieve consistent gasket contact, but it should not be used to compensate for a door that is unsafe, severely distorted or unable to close correctly.

Step 1: Measure the Head and Jamb Stops

Remove the seal from its packaging and measure:

  • The head stop across the top of the frame
  • The hinge-side jamb stop
  • The closing-side jamb stop

Allow for mitred corner joints where the head length meets the two jamb lengths.

Measure each section individually. Do not assume that both jambs are exactly the same length or that the frame is perfectly square.

Step 2: Remove the Decorative Cover Strips

Remove the decorative PVC cover strip from each aluminium carrier before cutting or fixing the seal.

Place the cover strips somewhere clean and protected so they do not become scratched, twisted or contaminated.

Keep each cover strip with its corresponding carrier length.

Step 3: Pull Back the Silicone Gasket

Pull the silicone gasket back from the section of aluminium carrier that needs to be cut.

This prevents the gasket from being damaged by the saw and allows the carrier to be cut accurately.

Do not pull or stretch the gasket excessively.

Step 4: Cut the Aluminium Carriers

Cut the aluminium carriers to the measured lengths using a suitable hand saw or power saw.

Allow for mitred joints at the upper corners where the head and jamb sections meet.

Use a suitable mitre box or cutting guide to create clean and accurate corner joints.

Support the carrier during cutting to avoid:

  • Bending the aluminium
  • Damaging the visible finish
  • Distorting the gasket channel
  • Creating rough or uneven cut edges

Remove any sharp burrs after cutting.

Step 5: Cut the Decorative Cover Strips

Measure and cut the decorative cover strips to correspond with the finished aluminium carrier lengths.

Cut the strips carefully so that they fit neatly within the carriers and do not overlap at the mitred corners.

Do not fit the cover strips permanently at this stage.

Step 6: Reposition and Cut the Silicone Gaskets

Slide the silicone gasket back into its correct position within each aluminium carrier.

Cut the gasket to the required finished length using a sharp knife.

Make sure the gasket reaches the ends of each carrier without being stretched, compressed or left short.

The upper corner gaskets should meet neatly when the head and jamb lengths are installed.

Step 7: Position the Seals on the Door Stops

Position the cut lengths against the existing door stops at the top and sides of the frame.

Check that:

  • The head section is level
  • The jamb sections are vertical
  • The upper mitred corners meet neatly
  • The silicone gasket faces the door correctly
  • The carrier does not obstruct hinges, locks or other hardware
  • The door can still close into the frame

Use the pre-slotted holes as a guide and mark the pilot-hole positions onto the door stops with a pencil.

Step 8: Drill Suitable Pilot Holes

Remove or hold back the seal and drill appropriate pilot holes at the marked fixing positions.

Select the pilot-hole size according to:

  • The supplied fixing screws
  • The door-stop material
  • The manufacturer’s recommendations

Take care not to drill into concealed wiring, hardware or other services.

For metal construction, use suitable self-drilling and self-tapping screws. Lorient states that these are available on request.

Step 9: Lightly Screw-Fix the Carriers

Position the aluminium carriers back against the door stops.

Lightly secure each length through the pre-slotted holes using the supplied screws.

Do not fully tighten the screws at this stage.

The slotted holes allow the carrier to be moved towards or away from the door face until the correct gasket compression is achieved.

Step 10: Check the Gasket Compression

Close the door and check for uniform contact between the silicone gasket and door face.

Lorient recommends placing a sheet of paper between the gasket and the door, then closing the door.

Pull the paper gently.

Resistance should feel firm and reasonably consistent around:

  • The head of the door
  • The hinge-side jamb
  • The closing-side jamb

If the paper pulls out too easily, move the carrier slightly towards the door to increase gasket compression.

If the gasket is excessively compressed or prevents the door from closing correctly, move the carrier slightly away from the door.

Repeat the test at several points until consistent contact has been achieved.

Step 11: Tighten the Fixing Screws

Once the position of the seal is correct, open the door and tighten all fixing screws.

Tighten the screws sufficiently to secure the aluminium carrier, but do not overtighten them or distort the profile.

Close the door again after tightening and repeat the paper test to confirm that the adjustment has not moved.

Step 12: Fit the Decorative Cover Strips

Fit the decorative PVC cover strips into the aluminium carriers to conceal the screws.

Press each strip fully into position along its complete length.

Check that the cover strips are:

  • Straight
  • Fully seated
  • Secure
  • Neatly cut at the corners
  • Free from visible damage

If a cover strip later needs to be removed, Lorient advises drilling a small hole at the bottom of the strip and pulling it out with a wire hook or another suitable tool.

Step 13: Complete the Final Door Check

Open and close the door several times.

Confirm that:

  • The door opens without excessive resistance
  • The door closes fully
  • The latch engages correctly
  • The seal remains securely attached
  • The gasket makes consistent contact
  • The upper mitred joints remain neat
  • The cover strips remain securely fitted
  • No part of the carrier obstructs the door

The installation must not prevent the door from opening, closing or latching correctly.

Installing with an Automatic Drop Seal

Lorient recommends combining the LAS7001 si with either:

  • LAS8001 si Drop Seal
  • LAS8004 Drop Seal

The LAS7001 si seals the head and jambs, while the drop seal treats the gap beneath the door.

Install and adjust the selected drop seal in accordance with its separate fitting instructions.

The perimeter and threshold seals should create continuous contact without interfering with each other or making the door difficult to operate.

Installing with a Face-Fixed Threshold Seal

Where the LAS7001 si is being combined with a face-fixed threshold seal, Lorient states that the perimeter seal must be fitted to the door frame first.

Once the head and jamb seals have been installed and adjusted, fit the face-fixed threshold seal according to its separate installation instructions.

Installation Tips

  • Measure the head and both jambs separately.
  • Allow for mitred upper corner joints.
  • Remove the decorative cover strip before cutting or drilling.
  • Pull back the silicone gasket before cutting the aluminium carrier.
  • Use a suitable saw and cutting guide for clean mitres.
  • Reposition and cut the silicone gasket after cutting the carrier.
  • Lightly secure the carrier before making final adjustments.
  • Use the slotted fixing holes to achieve consistent compression.
  • Use a sheet of paper to test contact around the complete perimeter.
  • Do not over-compress the silicone gasket.
  • Make sure the door continues to close and latch correctly.
  • Fit the perimeter seal before a face-fixed threshold seal.
  • Treat the gap beneath the door for effective acoustic and smoke containment.
  • Do not remove or interfere with any required intumescent fire seals.

Maintenance Advice

Inspect the LAS7001 si periodically as part of the door’s normal inspection and maintenance programme.

Check for:

  • Loose fixing screws
  • Movement of the aluminium carrier
  • Damage, tearing or hardening of the silicone gasket
  • Missing or loose decorative cover strips
  • Dirt or debris affecting gasket compression
  • Changes in the alignment of the door
  • Failure of the door to close or latch properly
  • Uneven contact around the head and jambs

Clean the seal carefully using a soft cloth and a suitable mild cleaning product.

Avoid abrasive tools or aggressive chemicals that could damage the silicone gasket, aluminium finish or PVC cover strip.

If the door drops on its hinges or its alignment changes, readjust the perimeter seal so that consistent contact is maintained without creating excessive closing resistance.

Important Performance Note

Correct installation and adjustment are essential to achieving useful acoustic and smoke containment.

The silicone gasket should make continuous contact around the head and jambs, but it must not prevent the door from operating correctly.

Final performance will also depend on:

  • The construction of the door leaf
  • The door frame
  • The selected threshold or drop seal
  • Glazing and ironmongery
  • The frame-to-wall junction
  • The surrounding construction
  • The overall installation quality

For certified acoustic, smoke or fire-resisting doorsets, follow the relevant doorset evidence and project specification in addition to the general fitting guidance above.

Delivery Options

Delivery Costs

Let us know where you are so we can calculate your delivery.

Visit our Delivery Help Centre page for the latest information about delivery.

A pallet service is required on larger items.

The standard pallet service time scale is an estimated 2-7 working days.

We have Next Day, Specific Day and Saturday options, which you can choose at the time of placing your order (UK mainland only).

When your order is processed and given to our courier, you will be contacted to arrange a suitable delivery date.

Our standard pallet service offers delivery to the kerbside. Couriers will not be able to move pallets or goods inside the property.

For parcel deliveries, we will use a courier service.

The standard parcel service time scale is an estimated 2-7 working days.

We have Next Day, Specific Day and Saturday options, which you can choose at the time of placing your order (UK mainland only).

Each item will be carefully packaged and distributed to our courier after being dispatched from our warehouse.

You can collect your order from our store. At checkout select "Local Pickup". We will notify you when your order is ready for collection.

Some postcodes are classed as remote by our delivery partners. If your address falls within one of these areas, additional delivery charges may apply.

  • Highlands and Islands
  • Parts of Scotland
  • Isle of Man
  • Northern Ireland
  • Remote rural postcodes

If you are unsure whether you live in a remote area or not, please contact our customer services team at [email protected]

If you are unsure whether you live in a remote area or not, please contact our customer services team at [email protected]

Delivery & Returns FAQs

If you are not home when delivery is attempted, the courier will usually leave a card or contact you with the next steps.

Depending on the courier and service used, they may attempt re-delivery, leave the parcel in a safe place, or take it back to the depot.

For pallet deliveries, someone normally needs to be available to accept the goods, as these are delivered kerbside and cannot usually be left unattended.

If you need to make a change to your order, please contact us as soon as possible after placing it.

We can usually make changes before the order has been processed or dispatched, but once it has entered production, packing, or shipping, changes may no longer be possible.

Our team will let you know what can be amended and whether any additional charges apply.

If an item is currently out of stock, please contact us to check availability.

Some products can still be ordered on a lead time basis, while others may be temporarily unavailable from the supplier.

We will advise you on the expected timescale and whether a suitable alternative is available.

In some cases, parcel deliveries may be left with a neighbour if you have given delivery instructions and the courier allows it.

Pallet deliveries are less flexible, as they usually require the goods to be accepted in person at the delivery address.

If you would like delivery left with a neighbour where possible, please let us know in advance and we will note this on the order.

Returns

For further information on our returns process, please check out our Returns Information Page.
Please note:
  • Delivery times are estimates and may vary depending on stock, courier availability, order size, and your postcode.
  • Pallet deliveries are usually kerbside only and require someone to be available to accept the goods.
  • Remote areas may incur additional delivery charges or longer delivery times.
  • Please check your order on arrival and report any damage or missing items as soon as possible.
  • Do not book installers or tradespeople until your goods have arrived and been checked. We are not liable for installer costs, delays, or consequential loss.
Essential items

Before you continue, there are some essential items which we recommend you may need.

Added to basket
Proceed to checkout

Get 10% Off Your First Order

Sign up today and we’ll send your discount code straight to your inbox.