SKU: N/A

Lorient LAS8007 SI Drop Seal

(0 Review)
£0.00
Show VAT
1
Earliest delivery: Calculating... Checking dispatch time...
  • Standard (tracked 48)
    £7.95 for 2-3 working days
  • Next Day (tracked 24)
    £9.95 for Next working day aim
  • Signed Delivery (signed for 24)
    £11.95 for Next working day aim
  • Guaranteed
    £16.95 for 2-3 working days
  • Local Pickup
    FREE - Collection from our Bristol warehouse

Lorient LAS8007 si Drop Seal

Lorient LAS8007 si Drop Seal is a heavy-duty, fully mortised automatic door-bottom seal designed to reduce sound, smoke, draught and light transfer through the gap beneath a door.

The seal is recessed into a machined groove in the bottom edge of the door, leaving only the silicone sealing gasket and end plates visible once installation is complete.

Its spring-loaded mechanical system automatically lowers the gasket as the door closes and retracts it when the door opens. No electrical connection is required.

The LAS8007 si is the fully mortised version of the Lorient LAS8006 si.

What is the LAS8007 si used for?

The LAS8007 si is installed within the bottom edge of a door to seal the gap between the door leaf and the floor, sill or threshold plate.

Unsealed gaps beneath doors can allow sound, smoke, draughts and light to pass between adjoining spaces. The LAS8007 si closes this gap automatically when the door shuts and lifts clear when the door opens.

It is commonly used for:

  • Reducing sound leakage beneath doors
  • Supporting smoke containment at the threshold
  • Reducing draughts between adjoining spaces
  • Limiting visible light beneath a closed door
  • Providing a concealed door-bottom sealing solution
  • Completing an acoustic sealing system with suitable perimeter seals
  • Sealing onto a suitable floor, sill or threshold plate

How does the LAS8007 si work?

The LAS8007 si contains a mechanical drop-seal system operated by an actuator button at the hinge side of the door.

As the door closes, the actuator button contacts the door stop. This activates the internal mechanism and lowers the flexible silicone gasket onto the floor, sill or threshold plate.

When the door begins to open, pressure is released from the actuator button and the gasket lifts clear of the floor after only a few millimetres of door movement.

This helps reduce:

  • Drag across the floor
  • Wear to the silicone gasket
  • Door-opening resistance
  • Damage to adjoining floor finishes
  • Noise caused by a gasket scraping across the floor

Fully mortised installation

The LAS8007 si is a fully mortised drop seal.

It is installed inside a groove machined along the bottom edge of the door. Lorient’s current fitting guide specifies a groove measuring:

  • 21mm wide
  • 44mm deep

Once fitted, the aluminium housing is concealed within the door leaf, creating a discreet finish.

Mortised installation is generally better suited to new doors, workshop preparation or doors that can safely accommodate the required groove.

Acoustic performance

The LAS8007 si has acoustic test evidence of up to Rw 39dB in accordance with BS EN ISO 10140-1:2010+A2:2014, Annex J.

The quoted acoustic performance applies to the relevant tested complete door assembly and sealing arrangement. It is not a standalone 39dB rating for the drop seal itself.

Final acoustic performance will depend on:

  • The construction and mass of the door leaf
  • The door frame
  • The perimeter sealing system
  • The adjustment of the drop-seal gasket
  • The floor or threshold surface
  • Glazing and door hardware
  • The frame-to-wall junction
  • The quality of installation

For effective acoustic containment, suitable seals should also be installed around the head and jambs of the door.

Smoke containment

The LAS8007 si has been tested for smoke containment to BS 476-31.1:1983 at ambient temperature.

It can contribute towards smoke containment by closing the otherwise open gap beneath a door.

The drop seal should be combined with suitable perimeter smoke seals around the head and jambs. Final smoke performance depends on the construction, condition and tested configuration of the complete doorset.

Fire-door applications

The LAS8007 si carries Certifire reference CF5179 and UL classification reference R27972.

The current fitting guide also shows positive-pressure gasketing classification information for use with specified fire-door constructions.

These references should not be treated as a standalone UK fire-resistance rating for the drop seal.

Before installing the LAS8007 si on a fire-resisting door, confirm:

  • That the product is permitted by the doorset evidence
  • The approved door-leaf construction
  • The permitted groove dimensions and position
  • The approved fixing method
  • The compatible perimeter seals
  • The permitted threshold arrangement
  • That machining the door will not invalidate its certification

Self-levelling operation

The LAS8007 si is designed to self-level across slightly uneven floor or threshold surfaces.

The gasket begins to lower from the hinge side and adjusts across the doorway as the door reaches its closed position.

The seal movement can be adjusted independently of the fixing screws by turning the actuator button.

This allows the installer to achieve light and consistent contact without moving the aluminium housing.

What size gap can the LAS8007 si seal?

Lorient states a published operating range of:

  • Minimum gap: 1mm
  • Maximum drop: 15mm

The actuator should be adjusted so the silicone gasket touches the sill or threshold during the final closing movement of the door.

The gasket should make continuous contact without being excessively compressed.

Which doors can the LAS8007 si be used on?

The LAS8007 si is suitable for:

  • Single swing doors
  • Single-leaf doors
  • Double-leaf doors
  • Left-handed doors
  • Right-handed doors
  • Timber doors capable of accommodating the required mortise
  • Acoustic door assemblies
  • Smoke-control door assemblies
  • Suitable fire-resisting doorsets where covered by certification

The actuator button must be positioned at the hinge side so that it meets the door stop as the door closes.

Where can the LAS8007 si be used?

Suitable applications can include:

  • Offices and meeting rooms
  • Schools and education buildings
  • Hotels and hospitality premises
  • Healthcare environments
  • Apartment and residential developments
  • Recording and media rooms
  • Consultation and treatment rooms
  • Commercial fit-outs
  • Public buildings
  • Doors requiring a concealed acoustic or smoke seal

Can it be used with a threshold plate?

Yes. Lorient states that the LAS8007 si can be used with any suitable threshold plate.

A threshold plate provides a firm, smooth and consistent surface against which the silicone gasket can close.

This can be particularly useful where the existing floor is:

  • Carpeted
  • Uneven
  • Interrupted by grout joints
  • Formed from different adjoining finishes
  • Subject to wear or compression

Lorient illustrates the LAS8007 si with the LAS4011 100mm threshold plate, although other suitable threshold plates may be used where permitted by the project and doorset specification.

Can it be used with perimeter seals?

Yes. Lorient recommends using the LAS8007 si with a suitable perimeter seal.

The drop seal treats the gap beneath the door, while the perimeter seals treat the:

  • Head of the door
  • Hinge-side jamb
  • Closing-side jamb

Using both helps create a continuous sealing system around the complete door leaf.

Key benefits

  • Fully mortised installation — concealed within the bottom edge of the door.
  • Automatic operation — lowers when the door closes and retracts when it opens.
  • Up to Rw 39dB — acoustic test evidence is available for relevant complete door assemblies.
  • Smoke-test evidence — tested to BS 476-31.1:1983 at ambient temperature.
  • Heavy-duty construction — designed for demanding door applications.
  • Self-levelling mechanism — helps maintain contact across slightly uneven surfaces.
  • Adjustable drop — movement is controlled using the actuator button.
  • Independent adjustment — gasket movement can be changed without repositioning the fixing screws.
  • No electrical connection — operation is entirely mechanical.
  • Lower operating resistance — the gasket lifts when the door begins to open.
  • Suitable for either handing — compatible with right- and left-handed doors.
  • Suitable for single and double doors — can be used on single- and double-leaf configurations.
  • Compatible with threshold plates — can close onto a suitable smooth threshold surface.
  • Compatible with perimeter seals — suitable for use as part of a complete sealing system.
  • Suitable for wheeled traffic — the gasket retracts clear of the floor when the door opens.
  • Fixing holes pre-drilled — installation holes are provided through the fixing flanges.
  • Fixings and end caps supplied — includes the principal components required for installation.

Helpful advice before buying

Measure the door width and confirm that the door can safely accommodate a groove measuring 21mm wide and 44mm deep.

The LAS8007 si is supplied in fixed length increments and can only be shortened within Lorient’s stated cut-back limits.

Also check:

  • The gap beneath the door
  • The door thickness and internal construction
  • The position of internal rails, glazing or hardware
  • The hinge side of the door
  • The selected floor or threshold surface
  • The required acoustic or smoke performance
  • The doorset test evidence or certification
  • Whether machining the door is permitted

Do not route into a fire-rated, glazed, hollow or specialist door without first checking the door manufacturer’s instructions and certification.

Lorient LAS8007 si Drop Seal Technical Specifications

Lorient LAS8007 si is a heavy-duty, fully mortised automatic drop seal with a self-levelling silicone gasket. It is installed within a machined groove along the bottom edge of a door.

Product Specification

Product Name Lorient LAS8007 si Drop Seal
Manufacturer Lorient
Product Reference LAS8007 si
Product Type Automatic mortised door-bottom drop seal
Duty Classification Heavy duty
Installation Type Fully mortised
Related Product Fully mortised version of the LAS8006 si
Application Sealing the threshold gap beneath single and double swing doors
Operating Method Mechanical actuator lowers the gasket as the door closes and retracts it when the door opens
Power Requirement None — mechanically operated
Required Groove Width 21mm
Required Groove Depth 44mm
Approximate Gasket Width 40mm according to the current profile drawing
Published Minimum Gap 1mm
Published Maximum Drop 15mm
Seal Material Black or grey silicone rubber
Carrier Material Aluminium
Self-Levelling Yes — designed to adjust across slightly uneven floor or threshold surfaces
Adjustment Actuator-button adjustment independent of the fixing screws
Adjustment Direction Clockwise reduces movement; anti-clockwise increases movement
Door Types Single swing, single-leaf and double-leaf doors
Door Handing Suitable for right- and left-handed doors
Actuator Position Hinge side of the door
Use With Any suitable perimeter seal and any suitable threshold plate
Acoustic Test Standard BS EN ISO 10140-1:2010+A2:2014, Annex J
Acoustic Test Evidence Up to Rw 39dB within the relevant tested door assembly
Smoke Test Standard BS 476-31.1:1983 at ambient temperature
Durability Tested to 100,000 operating cycles
Containment Characteristics Contributes towards sound, smoke, draught and light containment
Wheeled Traffic Suitable; the gasket retracts when the door opens
Standard Finish Silver anodised aluminium with grey end caps and grey silicone rubber gasket
Non-Standard Gasket and End Caps Black end caps and black silicone gasket may be available subject to charges, minimum order quantities and additional lead times
Fixing Method Screw-fixed through pre-drilled holes in the fixing flanges
Fixing Screws Supplied
End Caps Two end caps supplied
Striker Button One striker button supplied
Certifire Reference CF5179
UL Certification Reference R27972
Positive-Pressure Classification 5DL3 classification shown in the current fitting guide
Standalone Acoustic Rating? No — Rw 39dB applies to a relevant tested complete door assembly
Standalone UK Fire Rating? No standalone FD rating is stated in the current product datasheet

Standard Lengths and Cut-Back Limits

Supplied Length Minimum Permitted Cut Length
335mm 275mm
435mm 335mm
535mm 435mm
635mm 535mm
735mm 635mm
835mm 735mm
935mm 835mm
1035mm 935mm
1135mm 1035mm
1235mm 1135mm

Cutting Restrictions

The LAS8007 si must only be cut from the end opposite the actuator button.

Do not shorten the seal below the minimum cut-back length stated for the supplied size. Cutting it too short can interfere with the internal spring and operating mechanism.

When cutting the seal:

  • Pull the silicone gasket back from the cutting area
  • Cut the aluminium sections to the required length
  • Remove all cutting swarf and debris
  • Shorten the internal carrier by a further 3mm
  • Refit the carrier retaining screw
  • Push the gasket back into position
  • Trim the gasket using a sharp knife

Suitable Applications

The LAS8007 si can be used on:

  • Single swing doors
  • Single-leaf doors
  • Double-leaf doors
  • Left-handed doors
  • Right-handed doors
  • Timber doors capable of receiving the required mortise
  • Acoustic doorsets
  • Smoke-control doorsets
  • Fire-resisting doorsets where supported by relevant certification
  • Internal commercial and public-building doors

Acoustic Performance Note

Lorient states acoustic test evidence of up to Rw 39dB in accordance with BS EN ISO 10140-1:2010+A2:2014, Annex J.

This figure applies to a complete tested door assembly and does not represent the independent sound reduction of the drop seal.

Final acoustic performance will depend on:

  • The construction and mass of the door leaf
  • The perimeter sealing system
  • The threshold surface
  • The drop-seal adjustment
  • Glazing and ironmongery
  • The door frame and surrounding wall
  • The installation workmanship

Smoke Performance Note

The current Lorient product information lists smoke-test evidence to BS 476-31.1:1983 at ambient temperature.

The drop seal must be used as part of a complete smoke-sealing arrangement. Suitable perimeter seals should be installed around the head and jambs of the door.

Final performance depends on the complete door construction and tested component arrangement.

Fire and Certification Note

The LAS8007 si is shown with Certifire reference CF5179 and UL classification reference R27972.

The fitting guide also states that the listed positive-pressure gasketing materials are intended for use with specified wood, composite and metal fire-door constructions.

These certification references must not be interpreted as an independent UK fire-resistance period for the drop seal.

For a fire-resisting door:

  • Confirm that the LAS8007 si is permitted by the doorset evidence
  • Confirm that the 21mm × 44mm mortise is permitted
  • Follow the specified fixing and installation arrangement
  • Do not remove required intumescent or smoke seals
  • Do not machine through internal door components
  • Follow the door manufacturer’s instructions

Threshold Compatibility

The LAS8007 si can operate directly against a suitable smooth floor or sill.

A threshold plate can provide more consistent contact where the existing surface is:

  • Soft
  • Uneven
  • Worn
  • Interrupted by grout joints
  • Formed from different adjoining finishes

The selected threshold plate must be compatible with the available clearance, 15mm maximum drop and applicable doorset evidence.

Handling and Storage

Store the LAS8007 si:

  • Flat and fully supported
  • In a clean and dry location
  • Protected from bending and impact damage
  • With the actuator button protected from impact
  • With the fixing flanges protected from distortion
  • With the silicone gasket protected from cutting or crushing

Do not allow dust, timber chips or metal swarf to enter the internal mechanism.

How to Install the Lorient LAS8007 si Drop Seal

Lorient LAS8007 si Drop Seal is fully mortised into a groove machined along the bottom edge of the door.

The seal should be positioned on the centre line of the door, with the actuator button at the hinge side.

The LAS8007 si must only be shortened from the end opposite the actuator button and must not be cut below Lorient’s stated minimum cut-back length.

Always check the current Lorient fitting guide and the evidence for the complete doorset before installation.

What You’ll Need

  • Lorient LAS8007 si drop seal in the appropriate length
  • Two supplied end caps
  • Supplied fixing screws
  • Supplied striker button
  • Tape measure
  • Pencil or suitable marker
  • Hand saw or power saw suitable for aluminium
  • Screwdriver
  • Power drill or hand drill
  • 2.5mm drill bit
  • Router
  • Long-series router bit suitable for the required groove
  • Router guide or fence
  • Sharp knife, scissors or snips
  • Long-nose pliers
  • File or deburring tool
  • Vacuum or extraction equipment
  • Suitable door supports or restraints
  • Safety glasses
  • Suitable gloves
  • Hearing protection
  • Suitable respiratory protection when routing timber

Before You Start

Inspect the door, frame and threshold before machining or fitting the seal.

Check that:

  • The door opens, closes and latches correctly
  • The hinges and frame are secure
  • The door can safely accommodate a 21mm-wide × 44mm-deep groove
  • The groove will not cut through internal rails, fixings, glazing or hardware
  • The seal can be positioned on the centre line of the door
  • The actuator button can be placed at the hinge side
  • The gap beneath the door is within the 1mm to 15mm operating range
  • The floor or threshold provides a suitable sealing surface
  • The selected seal length can be cut to the required size
  • The machining is permitted by any applicable doorset certification

Do not machine a fire-rated, hollow, glazed or specialist door until the proposed groove has been checked against the door manufacturer’s evidence.

Step 1: Check the Supplied Length

Remove the LAS8007 si from its packaging and identify:

  • The actuator-button end
  • The end from which the seal can be shortened
  • The supplied seal length
  • The minimum permitted cut-back length

The current cut-back limits are:

  • 335mm can be reduced to 275mm
  • 435mm can be reduced to 335mm
  • 535mm can be reduced to 435mm
  • 635mm can be reduced to 535mm
  • 735mm can be reduced to 635mm
  • 835mm can be reduced to 735mm
  • 935mm can be reduced to 835mm
  • 1035mm can be reduced to 935mm
  • 1135mm can be reduced to 1035mm
  • 1235mm can be reduced to 1135mm

Do not cut the seal below the minimum length stated for the supplied size.

Step 2: Remove and Support the Door

Remove the door from its hinges.

Lay the door securely on its side and restrain it so that it cannot move while being measured, routed or drilled.

Support the door across its full length to avoid:

  • Bending the door leaf
  • Damaging the faces or edges
  • Breaking glazing or decorative finishes
  • Allowing the door to move during routing

If the bottom edge is already correctly grooved to suit the LAS8007 si, clean and inspect the groove before continuing to the measuring and cutting stages.

Step 3: Mark the Seal Position

Measure and mark the seal position along the bottom edge of the door.

For optimum operation, Lorient instructs that the seal should be positioned on the centre line of the door.

Mark the complete routing area clearly.

Check that the proposed groove:

  • Runs straight along the door bottom
  • Is centred within the available door thickness
  • Does not conflict with internal components
  • Leaves adequate material on both faces of the door

Step 4: Machine the Mortise

Fit a suitable long-series cutter to the router and set the guide.

Machine a continuous groove along the bottom of the door measuring:

  • 21mm wide
  • 44mm deep

Route the groove in controlled passes rather than attempting to remove the full depth in a single pass.

Keep the router stable and maintain a straight, consistent groove.

Use appropriate extraction to control dust and chips.

Step 5: Clean and Check the Groove

Remove all timber chips, dust and debris from the groove.

Measure the finished mortise to confirm that it is:

  • 21mm wide
  • 44mm deep
  • Straight
  • Continuous
  • Free from obstructions
  • Wide enough for the seal without excessive force
  • Not so wide that the seal becomes loose

Dry fit the LAS8007 si housing to confirm that the fixing flanges sit correctly against the bottom edge of the door.

Step 6: Measure the Required Seal Length

Measure the width of the door at the bottom edge.

Subtract the combined thickness of the supplied end plates before marking the aluminium seal for cutting.

The finished drop seal should fit neatly across the door without the end caps binding against the frame or stops.

Check the required finished length against the minimum cut-back size for the supplied seal.

Step 7: Pull Back the Silicone Gasket

At the end opposite the actuator button, carefully pull the silicone gasket away from the section that needs to be cut.

Move enough gasket away from the cutting position to prevent the saw from damaging it.

Do not:

  • Cut from the actuator-button end
  • Stretch the gasket excessively
  • Cut through the gasket with the aluminium housing
  • Damage the internal carrier or operating mechanism

Step 8: Cut the Aluminium Sections

Using a suitable power saw or hacksaw, cut the aluminium housing to the marked finished length.

Support the seal securely while cutting to prevent vibration or distortion.

After cutting:

  • Remove all aluminium swarf
  • Remove sharp edges and burrs
  • Clean debris from the housing
  • Check that the fixing flanges remain straight
  • Confirm that the mechanism has not been damaged

Do not leave metal swarf inside the operating mechanism.

Step 9: Shorten the Internal Carrier

After cutting the external aluminium housing, the internal carrier must be shortened by a further 3mm.

Remove the small self-tapping screw from the top of the housing.

Slide the internal carrier slightly proud of the housing and mark the additional 3mm reduction.

Cut the carrier carefully, then:

  • Remove all swarf and sharp edges
  • Slide the carrier back into the housing
  • Refit the retaining screw
  • Check that the carrier moves freely

The internal carrier must not project beyond the finished aluminium housing.

Step 10: Reposition and Trim the Gasket

Push the silicone gasket back into its normal position.

Allow it to sit naturally without stretching or bunching.

Trim the gasket to the finished length using a sharp knife, scissors or suitable snips.

The gasket should finish neatly within the end-cap arrangement without being stretched tight or left excessively long.

Step 11: Position the Seal in the Groove

Place the LAS8007 si into the machined groove.

Make sure the actuator button is positioned at the hinge side of the door.

Check that:

  • The seal sits fully within the groove
  • The housing is straight
  • The fixing flanges sit flat against the door bottom
  • The actuator button moves freely
  • The gasket is not trapped
  • The end caps can be installed correctly

Step 12: Mark and Drill the Fixing Holes

Use the pre-drilled holes in the fixing flanges to mark the pilot-hole positions on the bottom edge of the door.

Remove or hold the seal aside and drill suitable pilot holes using the 2.5mm drill bit specified in the current fitting guide.

The pilot-hole depth must suit:

  • The supplied fixing screws
  • The door construction
  • The available fixing material
  • The doorset manufacturer’s requirements

Do not drill into concealed door hardware, glazing channels or structural components.

Step 13: Screw-Fix the Seal

Return the LAS8007 si to the groove and secure it using the supplied screws.

Tighten the screws evenly through the fixing flanges.

Do not overtighten the fixings, as this could:

  • Distort the aluminium housing
  • Damage the fixing flanges
  • Restrict the internal mechanism
  • Damage the bottom edge of the door

Check that the housing remains straight and firmly seated within the mortise.

Step 14: Fit the End Caps

Fit the supplied end caps to both ends of the seal.

Make sure each cap is fully seated and does not interfere with:

  • The actuator button
  • The silicone gasket
  • The internal carrier
  • The operation of the door

The end caps should finish neatly against the edges of the door.

Step 15: Rehang the Door

Carefully return the door to its frame and refit it to the hinges.

Confirm that:

  • The hinges are securely fixed
  • The door hangs correctly
  • The drop seal does not contact the floor while the door is open
  • The actuator button aligns with the hinge-side stop
  • The door can open and close freely

Fit the supplied striker button where required so that the actuator meets a suitable contact surface as the door closes.

Step 16: Test the Drop-Seal Operation

Open and close the door while observing the silicone gasket.

The gasket should:

  • Remain lifted while the door is open
  • Begin lowering as the door approaches the frame
  • Contact the floor or threshold during the final closing movement
  • Make contact across the width of the doorway
  • Retract as the door begins to open

Check that the door continues to close and latch correctly.

Step 17: Adjust the Actuator Button

Pull the actuator button clear of the housing to access the threaded adjustment.

Where the button is flush or recessed, use long-nose pliers to pull it out carefully.

Hold the threaded rod firmly and turn the actuator button:

  • Clockwise — reduces the amount of seal movement.
  • Anti-clockwise — increases the amount of seal movement.

Make small adjustments and test the door after each change.

For optimum performance, the silicone gasket should touch the sill or threshold during the final closing movement.

Step 18: Check Self-Levelling Contact

Close the door and inspect the gasket across its complete width.

Check that:

  • The hinge-side end makes contact
  • The closing-side end makes contact
  • The centre makes contact
  • There are no visible gaps
  • The gasket is not excessively compressed
  • The gasket is not being forced sideways

Where the floor is too uneven or soft, install a suitable threshold plate to provide a smoother sealing surface.

Step 19: Complete the Final Door Check

Open and close the door several times.

Confirm that:

  • The door opens freely
  • The door closes completely
  • The latch engages correctly
  • The gasket retracts when the door opens
  • The gasket contacts the threshold when the door closes
  • The housing remains securely fixed
  • The end caps remain in position
  • The actuator meets the striker correctly
  • The seal does not scrape across the floor
  • The installation does not impede the door

Installing with Perimeter Seals

Lorient recommends using the LAS8007 si with a suitable perimeter seal.

The perimeter seal treats the gaps around the:

  • Head of the door
  • Hinge-side jamb
  • Closing-side jamb

The LAS8007 si treats the remaining gap beneath the door.

For tested acoustic, smoke or fire performance, use the complete component arrangement stated in the applicable doorset evidence.

Installing with a Threshold Plate

A suitable threshold plate can provide a firm and level contact surface beneath the drop seal.

This is useful where the existing floor is:

  • Carpeted
  • Uneven
  • Interrupted by grout joints
  • Subject to high levels of wear
  • Formed from different adjoining materials

The threshold plate must not reduce the available clearance below the operating requirements of the drop seal.

After installing the threshold plate, readjust the actuator so the gasket makes light and consistent contact during the final closing movement.

Installation Tips

  • Confirm that the door can safely accommodate a 21mm × 44mm groove.
  • Check the doorset certification before routing a fire-rated door.
  • Position the mortise on the centre line of the door.
  • Use controlled router passes rather than cutting the full depth at once.
  • Clear all timber dust and chips from the groove.
  • Check the permitted cut-back length before cutting.
  • Only cut from the end opposite the actuator button.
  • Pull back the gasket before cutting the aluminium.
  • Shorten the internal carrier by a further 3mm.
  • Remove all metal swarf from the mechanism.
  • Install the actuator button at the hinge side.
  • Use the pre-drilled flange holes for screw fixing.
  • Do not distort the housing by overtightening the screws.
  • Adjust the actuator in small increments.
  • Avoid excessive gasket compression.
  • Use a threshold plate where the floor does not provide a suitable sealing surface.
  • Check that the door continues to close and latch correctly.

Maintenance Advice

Inspect and test the LAS8007 si periodically as part of the door’s normal maintenance programme.

Check for:

  • Loose fixing screws
  • Movement of the aluminium housing
  • Loose or missing end caps
  • Damage to the silicone gasket
  • Dirt beneath the gasket
  • Incorrect actuator adjustment
  • Damage to the actuator or striker button
  • Changes in door alignment
  • Failure of the gasket to retract
  • Failure of the door to close or latch

Clean the gasket and threshold using a soft cloth and a suitable mild cleaning product.

Avoid abrasive tools, aggressive chemicals or unapproved lubricants.

Readjust the actuator if the door settles, the hinges move or the threshold level changes.

Important Performance Note

Correct machining, cutting, positioning and adjustment are essential to the performance of the LAS8007 si.

The gasket should make continuous contact with the sill or threshold during the final closing movement, but it must not be adjusted so heavily that it prevents the door from operating correctly.

Final acoustic, smoke and fire performance depends on the complete door assembly, including:

  • The door leaf
  • The frame
  • The perimeter sealing system
  • The threshold plate or floor surface
  • The door hardware
  • The surrounding construction
  • The installation workmanship

For certified acoustic, smoke or fire-resisting doorsets, follow the applicable test evidence, assessment and door manufacturer’s instructions in addition to this general installation guidance.

Delivery Options

Delivery Costs

Let us know where you are so we can calculate your delivery.

Visit our Delivery Help Centre page for the latest information about delivery.

A pallet service is required on larger items.

The standard pallet service time scale is an estimated 2-7 working days.

We have Next Day, Specific Day and Saturday options, which you can choose at the time of placing your order (UK mainland only).

When your order is processed and given to our courier, you will be contacted to arrange a suitable delivery date.

Our standard pallet service offers delivery to the kerbside. Couriers will not be able to move pallets or goods inside the property.

For parcel deliveries, we will use a courier service.

The standard parcel service time scale is an estimated 2-7 working days.

We have Next Day, Specific Day and Saturday options, which you can choose at the time of placing your order (UK mainland only).

Each item will be carefully packaged and distributed to our courier after being dispatched from our warehouse.

You can collect your order from our store. At checkout select "Local Pickup". We will notify you when your order is ready for collection.

Some postcodes are classed as remote by our delivery partners. If your address falls within one of these areas, additional delivery charges may apply.

  • Highlands and Islands
  • Parts of Scotland
  • Isle of Man
  • Northern Ireland
  • Remote rural postcodes

If you are unsure whether you live in a remote area or not, please contact our customer services team at [email protected]

If you are unsure whether you live in a remote area or not, please contact our customer services team at [email protected]

Delivery & Returns FAQs

If you are not home when delivery is attempted, the courier will usually leave a card or contact you with the next steps.

Depending on the courier and service used, they may attempt re-delivery, leave the parcel in a safe place, or take it back to the depot.

For pallet deliveries, someone normally needs to be available to accept the goods, as these are delivered kerbside and cannot usually be left unattended.

If you need to make a change to your order, please contact us as soon as possible after placing it.

We can usually make changes before the order has been processed or dispatched, but once it has entered production, packing, or shipping, changes may no longer be possible.

Our team will let you know what can be amended and whether any additional charges apply.

If an item is currently out of stock, please contact us to check availability.

Some products can still be ordered on a lead time basis, while others may be temporarily unavailable from the supplier.

We will advise you on the expected timescale and whether a suitable alternative is available.

In some cases, parcel deliveries may be left with a neighbour if you have given delivery instructions and the courier allows it.

Pallet deliveries are less flexible, as they usually require the goods to be accepted in person at the delivery address.

If you would like delivery left with a neighbour where possible, please let us know in advance and we will note this on the order.

Returns

For further information on our returns process, please check out our Returns Information Page.
Please note:
  • Delivery times are estimates and may vary depending on stock, courier availability, order size, and your postcode.
  • Pallet deliveries are usually kerbside only and require someone to be available to accept the goods.
  • Remote areas may incur additional delivery charges or longer delivery times.
  • Please check your order on arrival and report any damage or missing items as soon as possible.
  • Do not book installers or tradespeople until your goods have arrived and been checked. We are not liable for installer costs, delays, or consequential loss.
Essential items

Before you continue, there are some essential items which we recommend you may need.

Added to basket
Proceed to checkout

Get 10% Off Your First Order

Sign up today and we’ll send your discount code straight to your inbox.